Call now020 8194 8736
  1. Home
  2. Hot Water Cylinders

Hot Water Cylinder Repair & Replacement in Abbey Wood

Vented and unvented cylinders repaired and replaced, with immersion heaters and valves.

Hot Water Cylinders in Abbey Wood

What's included

  • Leaking and failed cylinders replaced
  • Unvented cylinder installation and servicing
  • Immersion heaters and thermostats
  • No hot water or lukewarm water

Hot Water Cylinders for homes and businesses in Abbey Wood

Has the water from your cylinder turned lukewarm, or stopped coming hot at all? The cylinder is rarely to blame. More often the thermostat, the motorised valve or the immersion heater has failed. So we test those three before anything else. If the cylinder itself leaks or is heavily scaled, we fit a modern replacement of the correct size.

Two types: vented and unvented

A loft tank feeds a vented cylinder, and the pressure is modest. The unvented kind takes water directly off the mains, giving strong pressure at each tap and a loft cleared of tanks. Your incoming supply must be up to it, so we measure the flow and pressure of your mains before recommending an unvented model.

The legal side of unvented cylinders

An unvented cylinder holds hot water under pressure, with safety devices that have to work. First, installation is notifiable under Part G of the Building Regulations. Next, the installer must hold G3, the qualification for unvented hot water. Then the cylinder should be serviced each year. If your taps run poorly, the supply may be the cause; see weak water pressure.

What each part of the system does

The cylinder is a tank wrapped in insulation, holding water heated from the boiler, from an immersion heater, or from both. With the indirect type, hot water from the boiler runs round a pipe coil within the tank, and the coil warms the stored water; the two never meet.

A thermostat strapped on the cylinder's side signals the boiler once the stored water has reached temperature. A motorised valve steers the heat: to the radiators, to the cylinder, or to the two together. The immersion heater, an electric element, runs on its own as a back-up. Knowing each part helps you describe a fault and helps us diagnose it.

Tracing the cause of cold taps

First, if the radiators still get warm yet the taps run cold, look to the cylinder side, where four causes are likely. The motorised valve has burned out or stuck, the cylinder's thermostat has failed, the programmer is wrongly set, or an airlock sits in the pipe that feeds the coil.

Next, if taps and radiators are both cold, the fault lies in the pump or boiler, a job for an engineer on the Gas Safe register. Then, if an immersion heater is your only source of hot water, suspect an element that has burned out or a thermal cut-out that has tripped. Last, merely tepid water adds two causes: a thermostat turned down too far, or a coil coated in scale.

Working out the right capacity

An undersized cylinder runs dry; an oversized one burns energy to keep water hot that no one draws. First, we count the people and the bathrooms and apply a rough guide. One bathroom wants around 120 to 150 litres; with two it is 180 to 210, and a bigger home wants 250 or above. Then, a fast-recovery cylinder heats up again quickly, so a smaller one may do.

Today's cylinders are much better insulated than older ones, so little heat escapes. After that, we check the cupboard's floor area and height, and the floor's strength, since a full cylinder weighs a lot. Finally, heat pump and solar systems call for a cylinder with bigger or extra coils.

Moving from vented to unvented

Many households swap the loft tanks and old vented cylinder for an unvented one, freeing the loft and giving showers at mains pressure. First, we measure your incoming supply: an unvented cylinder, as a guide, wants roughly 1.5 bar and a flow of about 20 litres a minute.

Next, a supply that falls short may need a new, bigger pipe laid from the street; our page on renewing the water main and stopcock covers it. Then, the pipe that discharges from the safety valves has to end outdoors at a spot that is safe and in view. Finally, any shower that used a pump must be changed; see our shower fitting page.

The immersion heater and how we change one

The immersion heater is a reliable, simple back-up and, on any off-peak tariff, heats water economically. An element gives many years of service but fails in the end, sooner in hard water. The signs: the immersion gives no hot water, the circuit trips, or the water only gets warm. To change one, we first drain the cylinder until the water sits lower than the element.

Next, we undo the element using a special spanner. Then the new element goes in, along with a fresh seal. We unscrew with care, as an old copper cylinder distorts under excessive force. Last, the heater's thermostat has to incorporate a safety cut-out against overheating, a rule brought in following serious accidents.

The yearly service and safe temperatures

An unvented cylinder needs a yearly service by a person qualified for this work. It covers the strainer, the pressure reducing valve and the air gap or expansion vessel. Above all, the relief valves for pressure and temperature must each be shown to open. Skip the service and the maker's warranty generally becomes void.

Between services, drips of water at the discharge pipe outdoors are a warning you should not let pass. Keep stored hot water at 60 degrees or higher, which stops legionella bacteria growing. Water that hot can scald. Where older people or children are at risk, a thermostatic mixing valve should be fitted.

Arranging cylinder work in Abbey Wood

First, does a loft tank feed your cylinder or the mains, what age is it, and what has gone wrong? Next, a picture showing the cylinder with its surrounding valves and pipework gives us a lot to go on. Then say if your heating is gas, since a boiler fault has to go to a gas engineer.

If you want a replacement, we also need the number of people and bathrooms. Airing cupboards in Abbey Wood are frequently a tight fit, so we measure ahead of any quote. One more thing: when taps run weakly, the supply can be the reason. See poor pressure and its causes.

Hot Water Cylinders: common questions

How long does a hot water cylinder last?

A copper vented cylinder can last decades. Stainless unvented cylinders often carry a 25-year warranty, provided they are serviced.

Can you replace just the immersion heater?

Usually yes, without changing the cylinder. The electrical connection must be made safely and the heater's thermostat must have a safety cut-out.

What should I do while I wait for the plumber?

Turn the water off at the stopcock, usually under the kitchen sink, and open the cold taps to drain the pipes. If water is near electrics, switch off at the consumer unit and keep clear.

Need a plumber in Abbey Wood?

Call now for advice, a price or an emergency visit.

Call now020 8194 8736
Call 020 8194 8736